Product Description
Additional Information
Reviews (0) Questions (0)
| SPECIFICATIONS | |
| Brand | APC |
| Series | Smart-UPS |
| Model | SUVTP20KH4B4S |
| Output Power Capacity | 16 kW / 20 kVA |
| Max Configurable Power | 16 kW / 20 kVA |
| Nominal Output Voltage | 230V,400V 3PH |
| Output Voltage Note | Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage |
| Efficiency at Full Load | 0.953 |
| Output Voltage Distortion | Less than 5% at full load |
| Output Frequency | 47 - 53 Hz for 50 Hz nominal |
| Other Output Voltages | 380,415 |
| Crest Factor | 0.125694444 |
| Waveform Type | Sine wave |
| Output Connections | Hard Wire 4-wire (3PH + G) | Hard Wire 5-wire (3PH + N + G) | Screw Terminals |
| Bypass | Built-in Maintenance Bypass,Built-in Static Bypass | Input |
| Nominal Input Voltage | 400V 3PH |
| Input Frequency | 40 - 70 Hz (auto sensing) |
| Input Connections | Hard Wire 5-wire (3PH + N + G) |
| Input Voltage Range | 304 - 477 V |
| Other Input Voltages | 380,415 |
| Maximum Input Current | 27 A |
| Input Breaker Capacity | 50.0 A | Batteries and Runtime |
| Battery Type | VRLA |
| Included Battery Modules | 4 |
| Typical Recharge Time | 5 hours |
| RBC Quantity | 4 |
| Nominal Battery Voltage | +/-192 V (split battery referenced to neutral) |
| End of Discharge Battery Voltage | +/-154 V | Communications & Management |
| Interface Ports | DB-9 RS-232,Smart-Slot |
| Pre-Installed SmartSlot Cards | AP9631 |
| Control Panel | Multi-function LCD status and control console |
| Audible Alarm | Audible and visible alarms prioritized by severity |
| Emergency Power Off | Yes | Regulatory Approvals |
| Conformance | C-tick, CE, EN 50091-2, EN/IEC 62040-3, IEC 61000-3-2, IEC 61000-3-3, ISO 14001, ISO 9001, VFI-SS-112 | Environmental |
| Operating Environment | 32 to 104°F (0 to 40°C) |
| Operating Relative Humidity | 0 - 95% |
| Operating Elevation | 0 - 999.9 m |
| Storage Temperature | -60 to 104°F (-50 to 40°C) |
| Storage Relative Humidity | 0 - 95% |
| Storage Elevation | 0 - 15000 m |
| Online Thermal Dissipation | 3112.00 BTU/hr |
| Audible Noise | At 1 meter from surface of unit: 51.30 dBA |
| Protection Class | IP 20 | General |
| Color | Black |
| Dimensions (HxWxD) | 149.9 x 55.9 x 81.3 cm |
| Weight | 630 kg | Availability |
| Automatic internal bypass | Supplies utility power to the connected loads in the event of a UPS power overload or fault. |
| Generator compatible | Ensures clean, uninterrupted power to protected equipment when generator power is used. |
| Dual mains input | Increases availability by allowing the UPS to be connected to two separate power sources. |
| Scalable runtime | Allows additional run time to be quickly added as needed. |
| Battery modules connected in parallel | Delivers higher availability through redundant batteries. | Manageability |
| LCD display | Alpha-Numeric Display which displays system parameters and alarms. |
| InfraStruXure Manager Compatible | Enables centralized management via the APC InfraStruXure Manager. |
| SmartSlot | Customize UPS capabilities with management cards. |
| Network manageable | Provides remote power management of the UPS over the network. |
| Audible alarms | Provides notification of changing utility power and UPS power conditions |
| LED status indicators | Quickly understand unit and power status with visual indicators. |
| Programmable frequency | Ensures compatibility with different input frequencies. | Serviceability |
| Shippable with modules installed | Enables pre-installation UPS staging and testing and faster installation. |
| Automatic self-test | Periodic battery self-test ensures early detection of a battery that needs to be replaced. |
| Battery replacement without tools | Enables fast battery replacement, lowering Mean Time to Repair (MTTR). |
| Modular design | Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules. | Protection |
| Frequency and voltage regulation | Gives higher application availability by correcting poor frequency and voltage conditions without using the battery. |
| Cold-start capable | Provides temporary battery power when the utility power is out. |
| Safety-agency approved | Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. | Total Cost of Ownership |
| Input power factor correction | Minimizes installation costs by enabling the use of smaller generators and cabling. |
| Intelligent battery management | Maximizes battery performance, life, and reliability through intelligent, precision charging. |
| Manual maintenance bypass | Reduces installation costs by eliminating the need for an external mechanical bypass. |
| Temperature-compensated battery charging | Prolongs battery life by regulating the charge voltage according to battery temperature. | Marketing Features |
| Network manageable | Provides remote power management of the UPS over the network. |
| Manual maintenance bypass | Reduces installation costs by eliminating the need for an external mechanical bypass. |
| Dual mains input | Increases availability by allowing the UPS to be connected to two separate power sources. |
| Scalable runtime | Allows additional run time to be quickly added as needed. |
| Hot-swappable batteries | Ensures clean, uninterrupted power to protected equipment while batteries are being replaced |
| Input power factor correction | Minimizes installation costs by enabling the use of smaller generators and cabling. | Sustainability |
| EU CoC for UPS | Ensures that UPSs sold in the EU are highly efficient | Warranty Information |
| Warranty | Manufacturer's Warranty |
| Manufacturer's Site | Visit the manufacturer's website |
|---|---|
| Product Link | Visit the manufacturer's page for this product |